Designed for use
with
the STD Bus Systems, it's a versatile device that can be usedin the
newer
STD-32® systems as a solid choice for reading
displacementinformation.
The STD-5601 allows simple interfacing to two Temposonics
TMnon contacting absolute transducers. Temposonics
TMtransducers are completely solid state and utilize
magnetostrictive
action.Linear distances may be measured with a resolution of
0.0005-inch or
better at lengths up to 65 inches. The STD 5601 measures the time of
travel
of the sonic pulse generated by the transducers utilizing a start/stop
counter
with a 28 MHZ crystal oscillator time base. (Note: 56 MHZ crystal
oscillator
time base are also available).
xxyy +0 Read Update Status bit of Transducer 1 and Data bit 17xxyy +1 Read MSB of Transducer 1
xxyy +2 Read LSB and reset Update Status Bit of Transducer 1
xxyy +3 Read Update Status bit of Transducer 2 and Data bit 17
xxyy +4 Read MSB of Transducer 2
xxyy +5 Read LSB and reset Update Status Bit of Transducer 2
xxyy +6 Set Status Bit Transducer 1 (Normally used for diagnostics only)
xxyy +7 Set Status Bit Transducer 2 (Normally used for diagnostics only)
Notes: 1. XX is determined by CPU encoding of the IORQ* Signal
2. YY is determined by setting of dip switches on circuit board.
Digitron Electronics L.L.C. Stevenson, Washington 98648
(509)427-4005 fax(509)427-3632
Inquiries to: NOSPAM@digitronelec.com
(Replace the word "NOSPAM" with the word: controls)
Home | Board Edger | Cant Edger | STD Bus Card | ISA Bus Card | Servo Card | Line Card | Setworks Images | Trimmer-Sorter | Planer Head Height | Transducer Theory